Special Advertising Section
This review of Laboratory Equipment's Product Showcase brings you products/services of interest. Use our click through option for additional information. |
 |
RS232 Direct into Excel
WinWedge software simplifies data input from any RS232 lab instrument
directly into Excel or any Windows application. Easily collect data
from balances, meters, analyzers, sensors and other serial or TCP/IP
output devices. Visit www.TALtech.com for information, user
applications and comments or call 800-722-6004 if you have any
questions.
|
|
Fiber Optic Oxygen Sensors
FOXY Fiber Optic Oxygen Sensors are spectrometer-coupled chemical sensors for
analysis of dissolved and gaseous oxygen pressure. In FOXY set-ups, a
fluorescence method measures the partial pressure of dissolved or gaseous
oxygen. Sensing formulations are coated on probe tips and available for
aqueous as well as non-aqueous vapors and liquids, and include our new HIOXY
coating for hydrocarbon environments such as commercial and military aviation
fuels, gasoline, diesel, glycol, hydraulic fluids and wine.
Email
Learn More >>>
| |
CANNON Instrument Company Has Introduced a New Type of Automatic Viscometer.
The miniAV®, manufactured by CANNON, automates sample measurement and tube
cleaning, the most labor-intensive parts of the kinematic viscosity
measurement process. The new instrument stands just over 20 inches tall and
occupies roughly the same footprint as a tabletop rotational viscometer. The
miniAV has a built-in temperature bath that controls temperature with the
high level of precision demanded by the ASTM D 445 kinematic viscosity method.
Learn More >>>
| |
Precise, Stable ICP Performance
Shimadzu’s simultaneous ICPE-9000 Plasma Emission Spectrometer features
multi-functional ICPEsolution software and a wealth of innovative technology,
ensuring stable, long-term performance and precise/reliable high-speed
measurements with high resolution. Software features include a Method
Development Assistant and a database calibration function. Advanced
technology includes a large-scale CCD detector and an Echelle spectrometer
to minimize noise and increase sensitivity, mini torch technology, and a
vacuum spectrometer equipped with semiconductor detectors.
Email
Learn More >>>
| |
Radleys StarFish multi-experiment workstation—from Brinkmann
Simply heat and stir, or perform more complex experiments: Radleys StarFish
makes your experiments easier, your results more accurate, your downstream
chemistries more reliable—and improves the overall productivity of your lab!
StarFish fits all leading brands of stirring hotplates and accepts a wide
range of standard glassware, including scintillation vials, test tubes,
beakers—even round-bottomed flasks! It can also easily handle additions and
reflux under an inert atmosphere.
Learn More >>>
| |
New Humidity Transmitter Series from Vaisala
The Vaisala HUMICAP® Humidity/Temperature Transmitter Series HMT330 is
optimized for HVAC and demanding industrial applications. Six models cover
0…100 %RH, a wide temperature range -70…+180 °C (365 °F), pressure 0…100 bar
(1450 psi). In humid or harsh chemical conditions, the warmed probe and
chemical purge function maintain reliability. Features include a unique
graphical trend display with one year of historical data. Call: (888) VAISALA (824-7252)
Email
Learn More >>>
| |
NEW! 3-D Electron Roughness Analyzing Microscope
The new 3D e-RAM is a field emission scanning electron microscope
specifically developed for surface roughness analysis and topographic reconstruction. 3-D roughness measurements are obtained using signals from
a 4-channel SE detection system that enables quantitative surface roughness
measurements to a vertical resolution specification of 1 nm. The major
benefit of this system is that it can produce AFM quality data, precisely
where you need it, with a wider lateral and vertical measurement range.
Email
Learn More >>>
| |
Ultra Low Temp Chillers, Baths, Traps and Probes
CHILLERS to -90C. 500W heat removal at -80C. TRAPS: Titanium and teflon
design captures corrosive vapors to -100C. BATHS to -100C; eliminate dry
ice and LN2. IMMERSION PROBES to -100C; transition to -50C in 30 minutes.
Two week availability on most systems. Email
Learn More >>>
|
|
| |
|
|